Search found 39 matches
- Fri May 31, 2013 5:49 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Reading serialized Blobs & Deserialize the blob
- Replies: 1
- Views: 1808
Reading serialized Blobs & Deserialize the blob
We are reading a blob from Microsoft SQL Server which has serialized information. I need to read this blob - de-serialize this blob ( I have the schema for the serialized blob) and store this into Netezza DB. At a conceptual level - i understand that I would need to read this blob, de-serialize the ...
- Thu Nov 16, 2006 11:29 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: All objects in the Job become PLUG objects.
- Replies: 9
- Views: 4397
- Wed Nov 01, 2006 9:34 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Maximum No of jobs in a Project
- Replies: 10
- Views: 4811
Is the 32-bit default size a Datastage setting or is it at the OS level?? Stupid me.. Should have read this adjust the UVCONFIG file to set hashed files to default to 64BIT, then create new projects which will then be 64BIT sized repository files. believe 32 bit default setting is the datastage set...
- Wed Nov 01, 2006 9:30 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Maximum No of jobs in a Project
- Replies: 10
- Views: 4811
- Wed Nov 01, 2006 9:28 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: All objects in the Job become PLUG objects.
- Replies: 9
- Views: 4397
- Mon Oct 30, 2006 9:59 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Maximum No of jobs in a Project
- Replies: 10
- Views: 4811
- Mon Oct 30, 2006 5:05 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Maximum No of jobs in a Project
- Replies: 10
- Views: 4811
Maximum No of jobs in a Project
Can someone share if there is a limitation on the maximum number of jobs that can be supported by a single project in DataStage. Also incase there is No limit on the number of jobs, I would like to know what are the factor that could limit the no of jobs in a project? I was suggested by IBM support ...
- Sun Oct 29, 2006 11:03 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: All objects in the Job become PLUG objects.
- Replies: 9
- Views: 4397
Hi Ray, Thanks for the reply, though I am not sure if its a client problem, because when I tried opening the same job on other system, I got the same plug object appear again. Incase if it was a client issue I could have still opened the job at different system. Can you please help? Well the IBM Sup...
- Sat Oct 28, 2006 9:00 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: Jobs Not Opening Prpoerly
- Replies: 9
- Views: 3325
Rather than reindex, why not create a set of projects, export subsets of the big project and deploy into the new projects. Instead of having 2600 jobs in one project, look to manage this better. ... That means one should limit the number of jobs in the project.. Can you please suggest the maximum n...
- Sat Oct 28, 2006 8:39 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: All objects in the Job become PLUG objects.
- Replies: 9
- Views: 4397
All objects in the Job become PLUG objects.
Hi, I have come across this particular issue and would like to know if anyone have faced similar issues: The issue is that all the objects in the job are converted to Plug object. I would need to the reason behind this conversion. Also I cannot save a job using "Save as" option and also th...
- Thu Oct 12, 2006 12:55 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Is the server loaded?
- Replies: 1
- Views: 1723
Is the server loaded?
While running a sequence I get an error Error calling DSRunJob(<jobname>,code=-14 (Timed out while waiting for an event) I believe this timeout is because of processor unavilability. I say so because I found that one of the processes APT_PMsectionLeaderFlag is consuming most of my CPU resource for a...
- Wed Oct 11, 2006 4:26 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Sequential file
- Replies: 4
- Views: 2124
- Wed Oct 11, 2006 3:03 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Sequential file
- Replies: 4
- Views: 2124
Sequential file
I wanted to know if there is a restriction on the number of columns that can be defined for a sequential file. Is there a limitation on the size of the file that the datastage would support. I believe that there should be no limitation on the number of columns that can be defined in a sequential fil...
- Wed Oct 11, 2006 2:52 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Monitoring Jobs
- Replies: 7
- Views: 3449
- Mon Oct 09, 2006 11:05 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Monitoring Jobs
- Replies: 7
- Views: 3449
Thanks kirti for the reply, I would check these settings and let you know about the same. There is one more thing that I would want to know, Is there a way to export the log files out of datastage to create a seperate local log file (txt format) ? As I know that the log file in datastage is a hash f...