Search found 115 matches

by gsym
Mon Feb 12, 2007 4:35 pm
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Number of the week - Oconv code
Replies: 12
Views: 3340

ray.wurlod wrote:Alert your BA to the fact that that decision will mean that week #53 in the year has fewer than seven days, and that roll-ups by week will be invalid.
Yes, rollups will be a problem, never though of that. What is a possible solution for this dilemma ?
by gsym
Fri Feb 09, 2007 4:19 pm
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Number of the week - Oconv code
Replies: 12
Views: 3340

As far as I can ascertain, the first day of the first week starts on Jan 1st of the year.
by gsym
Fri Feb 09, 2007 4:17 pm
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Number of the week - Oconv code
Replies: 12
Views: 3340

oh, ok......guess I gotta find out the business rule required here then. Or just do it like DSguru suggested.

Thanks for the answers.
by gsym
Fri Feb 09, 2007 3:50 pm
Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
Topic: Number of the week - Oconv code
Replies: 12
Views: 3340

Number of the week - Oconv code

Hi there folks,

Can anyone tell me what the conversion code is to get the number of the week in a year corresponding to a supplied internal date using OCONV ?
by gsym
Fri Feb 09, 2007 2:27 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Calling Environment Variables in Basic Transformer
Replies: 9
Views: 2479

Thats ok buddy. Glad you got it resolved. Just mark it as resolved and have a cup of tea, or coffee :wink: Thanks DSguru ...... I guess sometimes one has to put his problems in writing to realize he's already got the solution or that there was no problem at all in the first place !! :o Guess I had ...
by gsym
Fri Feb 09, 2007 2:23 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Calling Environment Variables in Basic Transformer
Replies: 9
Views: 2479

Crap !!

I feel like a complete idiot !!

Ur right, I have already found the solution.

What was I thinking.....

Why don't I just delete this post :oops: :oops: :oops:
by gsym
Fri Feb 09, 2007 2:12 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Calling Environment Variables in Basic Transformer
Replies: 9
Views: 2479

You pass the environment variable as a job parameter. The problem is that I have been asked to only use specific environment variables in the jobs. No job parameters. I am doing it this way because the job is going to be executed using a control file and the values for all the environment variables...
by gsym
Fri Feb 09, 2007 1:01 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Calling Environment Variables in Basic Transformer
Replies: 9
Views: 2479

chulett wrote:So... does this need to be a Parallel job?

I am using the BASIC Transformer here because of the ease of using Iconv/Oconv functions. But I must use it in a parallel job.
by gsym
Fri Feb 09, 2007 12:34 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Calling Environment Variables in Basic Transformer
Replies: 9
Views: 2479

Calling Environment Variables in Basic Transformer

I am using a BASIC Transformer in a Parallel job to generate a calendar table. The values for the start and end dates for the calendar must be obtained from a couple of environment variables. How do I go about doing this in the BASIC Transformer. Now if it was just a Transformer stage I would create...
by gsym
Thu Jan 11, 2007 12:56 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: Oracle enterprise database stage error
Replies: 2
Views: 1725

Koti,

Search using "orchoracle". If my meory serves rite this was posted a couple days back and I guess the topic is marked resolved.

You mite want to see all the topics with Oracle stage marked "resolved"

BTW check where is your lib in LD_LIBRARY_PATH?

HTH

Cheers
by gsym
Fri Jan 05, 2007 9:46 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: XML Input Stage
Replies: 10
Views: 4780

The XPath on the output/columns tab has the following artist/text() artist/company/text() artist/company/price/text() so on so forth... I assume that the input/columns tab does'nt require an Xpath. Pl correct me. The xml file file format is making the output format go awry. I 'm using the TFR TRIM f...
by gsym
Wed Jan 03, 2007 10:26 am
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: how to create multiple rows from a row
Replies: 10
Views: 4276

here the fields (3,4,and 5) can have a single value or multiple values. dont know the maximum number of values for these fields.
how to do it?

Thanks
by gsym
Tue Jan 02, 2007 1:11 pm
Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
Topic: how to create multiple rows from a row
Replies: 10
Views: 4276

how to create multiple rows from a row

Hi Everyone, I have a file with tilda delimited(12 fields) and field3,field4,field5 can have one or multiple values separated by commas pepsi~1~1,2,3~001,002~hourly,salaried~200612~quarterly~1~U~50~peer group~pepsi report output should be: pepsi,1,1,001,hourly,200612,quarterly,1,U,50,peer group,peps...
by gsym
Thu Nov 09, 2006 4:16 pm
Forum: IBM QualityStage
Topic: match stage like names
Replies: 2
Views: 1579

But the problem is that name should not be changed?

Hi Ray

The problem is even through i figured rob is bobby in standardization, i am not allowed to change it.......but when i run thru standardization stage bob will we converted to robert., correct me if i am wrong....so is there any solution?
by gsym
Thu Oct 26, 2006 1:48 pm
Forum: IBM QualityStage
Topic: Match stage probabilities?
Replies: 4
Views: 2009

Thanks ray