Search found 52 matches
- Mon Jul 24, 2006 9:36 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Changing the resource disk/resourcescratchdisk over the time
- Replies: 3
- Views: 1392
- Mon Jul 24, 2006 1:49 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Changing the resource disk/resourcescratchdisk over the time
- Replies: 3
- Views: 1392
Changing the resource disk/resourcescratchdisk over the time
Hi all, Will it be a problem, if we change the path of resource disk/resource scratchdisk in the configuration file over the time? If we can change, then what happens to the files in the old path? Can we play around the scratch disk like deleting files as they were temporary when ds is down to free ...
- Thu Dec 08, 2005 1:44 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: DSPIPE_WAIT Writer timed out
- Replies: 3
- Views: 1964
- Wed Dec 07, 2005 10:01 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: ImplicitConversion:from Int64 to Int16-Without MessageHandle
- Replies: 2
- Views: 1053
ImplicitConversion:from Int64 to Int16-Without MessageHandle
Hi All, When we run our jobs, we are getting a warning like implicit conversion was done.And we were not supposed to have this as a warning at the sametime we don't want to use Message Handler. And we want to handle more conversions like this. Please let me know if you already handled anything like ...
- Wed Dec 07, 2005 8:15 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Compile Error:Job May be being monitored
- Replies: 4
- Views: 2550
- Wed Dec 07, 2005 6:51 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Compile Error:Job May be being monitored
- Replies: 4
- Views: 2550
Compile Error:Job May be being monitored
Hi All, When we are compiling a job, it is a giving an error that job may be being monitored . And we are unable to see the lock on this job using DS.TOOLS in administrator.And it is not allowing us to rename.Please pass your inputs if you already handled this error. Thanks in advance Koteswara Rao ...
- Wed Dec 07, 2005 6:46 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: DSPIPE_WAIT Writer timed out
- Replies: 3
- Views: 1964
DSPIPE_WAIT Writer timed out
hi all, We are getting a TRN,0 :dspipe_wait(2060316): Writer timed out waiting for Reader to connect. error while running one of our job. We are just trimming the data that we are getting from sequential file in a transformer. So please pass anyinputs if you already handled this error. Thanks in adv...