Search found 13 matches
- Tue Jun 03, 2008 7:13 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Environment variable transporter
- Replies: 13
- Views: 6593
- Mon Jun 02, 2008 2:41 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Environment variable transporter
- Replies: 13
- Views: 6593
Re: Environment variable transporter
Thanks for your quick reply
I got it now
Previously I did not copy from [EnvVarDefns] part in the file.
Just curious to know if there is any other way to copy Environment variable from Project to project
Thank you
I got it now
Previously I did not copy from [EnvVarDefns] part in the file.
Just curious to know if there is any other way to copy Environment variable from Project to project
Thank you
- Mon Jun 02, 2008 1:57 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: Environment variable transporter
- Replies: 13
- Views: 6593
Environment variable transporter
Hello Gurus, I created a New Project and would like to copy User defined Environment Variable from other project. As Ray said i copied last lines in DSParams file and past in New Project. It did not work for me. Just copy those rows from DSParams that you need in the new project, and make sure that ...
- Wed Mar 19, 2008 2:06 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: OCI lookup
- Replies: 18
- Views: 6885
- Wed Mar 19, 2008 1:42 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: OCI lookup
- Replies: 18
- Views: 6885
- Wed Mar 19, 2008 1:39 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: OCI lookup
- Replies: 18
- Views: 6885
- Wed Mar 19, 2008 1:35 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: OCI lookup
- Replies: 18
- Views: 6885
- Wed Mar 19, 2008 10:40 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: OCI lookup
- Replies: 18
- Views: 6885
what is the Query that you are using to do a lookup. Paste both the query, user defined and Generated. ... custom SQL SELECT MRE_0003_MBR_ID_SITE,MRE_3001_MBR_ID_1_3,MRE_3001_MBR_ID_4_5,MRE_3001_MBR_ID_6_9,lpad(MRE_3001_MBR_SEQ_N,2,0) FROM CCI_hipdwstage1.MbrElg MbrElg WHERE MRE_0003_MBR_ID_SITE=:1...
- Wed Mar 19, 2008 8:09 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: OCI lookup
- Replies: 18
- Views: 6885
Apology first I am really sorry I did not mean to say that even though it sounds like it. I did try reset. I did not get much info from that may be I missed, so I am going to paste Log reset messages DataStage Job 533 Phantom 24912 jobnotify: Unknown error [24937] DSD.StageRun full_MbrBill_Ld. full_...
- Tue Mar 18, 2008 2:07 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: OCI lookup
- Replies: 18
- Views: 6885
- Tue Mar 18, 2008 1:43 pm
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: OCI lookup
- Replies: 18
- Views: 6885
OCI lookup
Hello Guru's I would like to know if any one else faced similar problem and if yes please pass the solution. I did find some posts similar but not exact coming to the problem job fails at transformer stage due to abnormal termination at lookup and writes warring to log then aborts with core dump mes...
- Tue Sep 18, 2007 7:42 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: CRC32 Value different from project to project
- Replies: 5
- Views: 2128
- Tue Sep 18, 2007 7:32 am
- Forum: IBM<sup>®</sup> Infosphere DataStage Server Edition
- Topic: CRC32 Value different from project to project
- Replies: 5
- Views: 2128
CRC32 Value different from project to project
Hello, I am using crc32 function to calculate row value for type2 changes. I did crc32 on one data set in development project and used the same data set in UAT to do crc32. I expected both the values to be same but they are different. In short crc32 value in development is different from UAT for the...