Hey Amsh ,
I have tried 2nd option before but though I changed the meta data it does not help ,
thanks ,
I will discard the warning !
Search found 101 matches
- Tue Feb 28, 2006 12:19 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: null metadata
- Replies: 8
- Views: 3268
- Tue Feb 28, 2006 11:09 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: null metadata
- Replies: 8
- Views: 3268
- Mon Feb 27, 2006 3:17 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: null metadata
- Replies: 8
- Views: 3268
no null in the source
Hey Kumar ,
I do not have any null in the field then why to use modify stage (just curious),
I thought of using modify stage but confused with the fact that if there are no nulls in the source data why it is complaining about null ,
Thanks
I do not have any null in the field then why to use modify stage (just curious),
I thought of using modify stage but confused with the fact that if there are no nulls in the source data why it is complaining about null ,
Thanks
- Mon Feb 27, 2006 2:54 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: null metadata
- Replies: 8
- Views: 3268
null metadata
Hi all , My source data type is null but It does not have any null valuesas it is required field , my target field is not null , I am getting this warning : "When checking operator: When binding output interface field "TRANSACTION_DATE" to field "TRANSACTION_DATE": Convertin...
- Mon Feb 27, 2006 10:41 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: change capture warnings
- Replies: 9
- Views: 9591
thanks
Thanks Kumar,
- Mon Feb 27, 2006 9:54 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: change capture warnings
- Replies: 9
- Views: 9591
no warnings
Hey Kumar ,
Thanks a lot , u r really gr8 .
When I turned off RCP on project as well as job level , it did not work , I still got warnings , but when I turned it on at project level and turned it off at job level it worked ,
no more warnings due to change capture stage ,
thanks a lot
Thanks a lot , u r really gr8 .
When I turned off RCP on project as well as job level , it did not work , I still got warnings , but when I turned it on at project level and turned it off at job level it worked ,
no more warnings due to change capture stage ,
thanks a lot
- Mon Feb 27, 2006 8:58 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: change capture warnings
- Replies: 9
- Views: 9591
Change capture warnings
[quote="kumar_s"]RCP :?: :?: :?: Turn it off. Some times it might be turned off at project level, and may not be effective at job level. Care should be taken.[/quote] Hi kumar , thanks for the replay , I have turned it off at job level as well as at project level but then also it is giving...
- Fri Feb 24, 2006 4:50 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: change capture warnings
- Replies: 9
- Views: 9591
change capture warnings
Hi , this is not the new warning . I have read the number of post on this warnings ,The warning is : Change_Capture_28: When checking operator: Defaulting "TRANSACTION_AMOUNT" in transfer from "beforeRec" to "outputRec". I am using CC stage with the option explicit valu...
- Tue Feb 14, 2006 2:58 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: director run option
- Replies: 4
- Views: 1549
Re: director run
[quote="kwwilliams"]If you run the job from director with the warnings set to no limit, and it still bombs you have another problem.[/quote]
What is the solution ?
What is the solution ?
- Tue Feb 14, 2006 1:42 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: director run option
- Replies: 4
- Views: 1549
director run
Hey roy , Thanks for the replay , We have NLS warnings which we could not removed ( could not find solution ) few warnigs are due to conversion etc can u explain more about exception handler how we can eliminate warnings, Due to deadlines we could not get rid off all the warnings , as we had to move...
- Tue Feb 14, 2006 1:05 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: director run option
- Replies: 4
- Views: 1549
director run option
Hi All, We have the situation where all our jobs have more that 50 warnings , The sequence ran fine in the development , where we set the parameter in the designer as no limit in run option , When we exported to prod it is getting aborted , might be the resources problem , or might be warning issue ...
- Mon Feb 06, 2006 10:12 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: database sequence
- Replies: 4
- Views: 1292
seq.nextval
Hi sundar , In the target table , change the option to auto insert and update , copy insert part of the query and then change the option to user defined update , paste the insert part into update option , then wherever ur key column is ,that is , insert into tablename_key,............. values seq.ne...
- Tue Jan 24, 2006 8:23 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: sequence start from first stage
- Replies: 3
- Views: 1469
thanks
Thanks All,
I got it ,
Have a nice day ,
I got it ,
Have a nice day ,
- Mon Jan 23, 2006 1:51 pm
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: sequence start from first stage
- Replies: 3
- Views: 1469
sequence start from first stage
Hi all, I have sequence with 6 dimensions and 1 fact ( as mensioned in last post) Though "add checkpoint so sequenve is restartable on failure" is checked , when seq aborts , and if I compile and run the seq again it starts from first stage and not from the stage where it is aborted Am I d...
- Mon Jan 23, 2006 9:36 am
- Forum: IBM<sup>®</sup> DataStage Enterprise Edition (Formerly Parallel Extender/PX)
- Topic: sequencer
- Replies: 3
- Views: 1831
sequence
Hey ray , Thanks for the replay My sequencer is getting aborted as my fact job is getting aborted (some reason I wll check it ) The log is : seq..JobControl (DSRunJob): Waiting for job GRANT_APPLICATIONS_TEST to start seq..JobControl (DSRunJob): Waiting for job CopyOfD_Time1 to start seq..JobControl...